Customization: | Available |
---|---|
After-sales Service: | Free Online Technical Support |
Type: | UV Light Meter |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter
|
Value
|
Spectral response
|
230nm-280nm, λp = 254nm
|
Measuring range
|
0 - 20000 μW / cm²
|
Resolution
|
0.1μW / cm²
|
Relative indication error
|
±8%(relative to NIM standard)
|
Long wave response error
|
<>
|
Cosine characteristics (directional response) error
|
10%
|
Linearity error
|
±1%
|
Short-term instability
|
±1%( 30min after startup)
|
Fatigue characteristics
|
attenuation <>
|
Error of zero
|
±0.1% of full scale
|
Response time
|
<0.5>
|
Sampling speed
|
2048 times/second
|
Test hole diameter
|
¢=10mm
|
Power value storage interval
|
1s/10s/60s optional
|
Recording period
|
10 min / 100 min / 600 min
|
Bluetooth transmission distance
|
50 meters (open space)
|
Instrument size
|
148mm ×76mm ×26mm (L*W*H)
|
Probe size
|
Diameter 39mm × thickness 15mm
|
Probe wire length
|
1 meter
|
Weight
|
About 300 g
|
Display
|
240*160 dot matrix LCD
|
Battery
|
4 AAA alkaline dry batteries
|
Operating Temperature
|
0° to 40°C, <85%>
|
1. The difference between LS126A and LS125 UV light meters (UVALED-X0 and UVALED-X1 probe)?
The functions of the LS126A UV light meter and the LS125 UV light meter host + UVALED-X0 or UVALED-X1 probe are basically the same. The probe width of LS126A is only 7.2mm, and the diameter of the test hole is 3mm, which is suitable for UV light source detection in a narrow space; the test hole diameter of the UVALED-X0 probe is 10mm, which is suitable for the detection of UV LED plane light sources; the test hole diameter of UVALED-X1 probe is 1mm, it's suitable for the detection of UV LED point light sources.
2. What is the difference between the LS126C UV light meter and other instruments?
1. LS126C is equipped with a 1-meter test hook that meets the sterilization requirements of medical institutions as required by national standards.
2. LS126C has Bluetooth function and mobile APP, which can monitor data wirelessly at a certain distance to avoid UV damage when viewing data on site.
3.126C can set the timed shutdown time. The measurement data is automatically saved when the machine is turned off. The next time the machine will display the last test result. Unattended measurements can be achieved.
4. LS126C UV light meter comes with a real-time clock that traces the specific measurement time of the measurement results.For example, if you test 20 tubes continuously, you can check the specific test time of each tube.
5. LS126C has power graph display function and statistical function. The statistics function can record the real-time value, maximum value, minimum value, average value, measurement duration and test time during the test. The power graph can be used to analyze the luminous intensity after the lamp is lit.
6. LS126C UV light meter is equipped with a USB communication port and dedicated PC software. Multiple sets of test data can be exported to an excel form and test reports can be generated for easy archival records.
3. How many values of the ultraviolet germicidal lamp used in hospitals would be up to standard?
The "Technical Disinfection Technical Specifications" stipulates that the instrument is placed at a position of 1 m vertically under a 253.7 nm ultraviolet lamp. The irradiation intensity of the new ordinary 30W straight lamp is greater than 100 μW/cm2.
The irradiation intensity of the ultraviolet lamp must be greater than 70μW/cm2. Different wattages of UV lamps, the country has different testing standards, 30W straight tube type is the most commonly used.
4. What is the difference of the test results between the LS126C UV light meter and the UV intensity indicator card?
1.The ultraviolet intensity indicator card is irradiated with the ultraviolet germicidal lamp for 1 minute. The color of the ultraviolet light sensitive color block is compared with the standard color block to determine the irradiation intensity of the light tube. The color contrast varies from person to person, especially in the case where the color of the photosensitive color block is not much different from that of the standard color block. Whether the intensity of the ultraviolet lamp is up to standard can only be qualitative, which is very difficult to quantitatively confirm.
2. LS126C UV light meter directly displays the radiation intensity value of the germicidal lamp tube. The measurement accuracy of the instrument is ensured to meet the national metrology institute test standard.
5. Do you offer OEM and ODM service?
Yes. We can supply OEM and make customized design for any specific application.
6. How can we guarantee quality?
Always a pre-production sample before mass production; Always final Inspection before shipment;
7. What can you buy from us?
Colorimeter,Gloss meter,Coating thickness meter,window tint meter,UV meter, Leeb hardness tester, Ultrasonic thickness gauge.
8. What services can we provide?
Accepted Delivery Terms: EXW,DAP;
Accepted Payment Currency:USD,CNY;
Accepted Payment Type: T/T,Western Union;
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian.
10. Does the instrument have a warranty?
Guarantee period is 12 months, after the warranty, we also provide life-long paid or service.