Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value

Product Details
Customization: Available
After-sales Service: 24 Hours Free Online Technical Support
Warranty: 12 Months Warranty
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
OEM Services
The supplier provides OEM services for popular brands
ODM Services
The supplier provides ODM services
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (13)
  • Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value
  • Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value
  • Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value
  • Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value
  • Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value
  • Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value
Find Similar Products
  • Overview
  • Product Parameters
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
LS110A
Display
Digital
Product Name
Ls110A Solar Film Tester
UV Peak Wavelength
365nm
IR Peak Wavelength
940nm
Visible Light
380-760nm, Conform to Cie Photopic Luminosity Func
Resolution
0.1% (0-10%); 1% (10%-100%)
Measurement Accuracy
+-2% (Colorless and Uniform Transparent Materials)
Test Sample Size
>40mm* 40mm
Power Supply
Built-in Lithium Rechargeable Battery
Transport Package
Carton Box
Specification
27*24*12cm
Trademark
TANJN
Origin
China
HS Code
9030849000
Production Capacity
10000PCS/Month

Packaging & Delivery

Package Size
27.00cm * 24.00cm * 12.00cm
Package Gross Weight
1.200kg

Product Description

Product Parameters

LS110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and VL Transmission Value

Descriptions:
LS110A solar film tester can test light transmittance, infrared barrier rate and UV barrier rate simultaneously. The window tint meter is suitable for testing automobile solar film, automobile glass, architectural glass and other materials. The film uv tester consists of two parts, the main unit and the secondary unit, and adopts the split design, which is especially suitable for testing already installed glass or materials with larger size. With data lock function, take away the test sample data can be kept on the display screen, convenient to view the test data.

Features:
1. Split design, main unit and auxiliary machine in the middle of the self-super-strong magnetic force.
2. Simultaneous testing of light transmission, UV and IR rejection is available.
3. With data lock function, take away the test sample data can be maintained on the display screen.
4. Available in a one-two charging cable to charge both main and auxiliary units together, due to built-in rechargeable lithium battery.
5. The light transmittance detection instrument can test large thickness of glass with parallel light path design.
6. With laser alignment function to ensure measurement accuracy.

Specifications
Parameter
Value
UV peak wavelength
365nm
IR peak wavelength
940nm
Visible light
380-760nm, conform to CIE photopic luminosity function
Resolution
0%---10%: 0.1%; 10%---100%: 1%
Measurement accuracy
± 2% (colorless and uniform transparent materials)
Test sample size
Great than 40mm * 40mm
Weight
630 g
Dimension
130mm * 70mm * 84mm
Power supply
Built-in lithium rechargeable battery
 
Product Description

Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission ValueLs110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value
Packing List:

No.
Description
Quantity
Unit
1
LS110A window tint meter
1
Set
2
 Charger
1
Pcs
3
 User Manual
1
Pcs
4
 Certificate / warranty card
1
Pcs
5
Packing box dimension 25*21*7 cm
1
Pcs
6
One to two to charge cable
1
Pcs
Company Profile

Ls110A Split Window Glass Tint Transmission Meter Car Glass Light Transmittance Meter UV IR Rejection and Vl Transmission Value

FAQ

1. What is the difference between a metal film and an endothermic film?
The metal film is produced by a magnetron sputtering process. A large amount of metal elements are added and the has a good reflection ability to the infrared film. It is insulated by the principle of reflecting infrared rays. The absorption film is added with an infrared absorber during production and the infrared is absorbed by the film. It is insulated by the bsorption principle and secondary heat radiation will be generated after the heat absorption is saturated.
    
2. Why are 1400nm instruments so much more expensive than 940nm instruments?
It's all about the cost of raw materials. The cost of a 1400nm light source and receiver is much higher.
    
3. Can the window film transmission meter measure the insulation rate?
Our instrument measures the infrared rejection rate. The higher the infrared rejection rate, the higher the thermal insulation rate. Because visible light also has a small amount of heat, in the strict sense, the heat insulation rate needs to integrate visible light, infrared and ultraviolet heat insulation data. Ultraviolet heat is very small and visible light is beneficial. Therefore, infrared is the main source of heat, so the infrared rejection rate is basically equivalent to the thermal insulation rate.
    
4. What is the difference between LS300 and LS301?
The LS300 measures the real-time temperature (degrees Celsius) and the temperature difference. The LS301 has an additional function to measure the infrared rejection rate of 940nm than the LS300. At the same time, the LS301 also measures the real-time temperature value. 
    
5. What is the difference between 940nm and 1400nm instruments?
The two bands of 940nm and 1400nm are relatively representative bands. Most of the absorption films (heat-absorbing films) have better infrared blocking effect at 940nm, while the magnetron sputtering reflection film has better blocking effect at 1400nm such as metal film and ceramic nano film. Please choose the right instrument for your own film category.
 
6. Do you offer OEM and ODM service? 
Yes. We can supply OEM and make customized design for any specific application. 
 
 
7. How can we guarantee quality? 
Always a pre-production sample before mass production; Always final Inspection before shipment;

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now